Ultimately, we decided that the new wire was simply softer than what we had previously used. This manifested in soggy tetrodes that would be less likely to remain straight when turning down into the brain (resulting in instability over days). Further, it was difficult to get a good, clean final cut of the tetrodes. The wires would mush together instead of creating a nice four leaf clover pattern. These lumpy tips were more likely to short together during gold plating and may have been the reason why recordings would degrade over weeks instead of months or longer.
To solve the problem we switched to a new wire from a new supplier. After asking Amy Griffin what she uses in her lab, we switched to a chromium alloy supplied by Kanthal Palm Coast with the 'PAC 240' insulation. In contrast to the wire we replaced, this was much stronger thanks to the industrial grade insulation. The tetrodes were impressively stiff and the cuts seemed cleaner. The difficulty was, however, that the heating step in our tetrode making protocol, intended to fuse the wires together, simply didn't work. Additional heat or time helped (maximum heat, 6 passes at 6-10sec per pass) but didn't solve the problem. Finally, we found that asking Kanthal to coat the wire with 'Bond XTC', a heat activated bonding coating, made the best tetrodes we've seen to date.
The RO800 wire with PAC 240 insulation and Bond XTC coating tetrodes are incredibly stiff, cut very cleanly, and perform as well as I can ask for in the recording drives. I've had several animals with clear recordings for more than 8 months and have repeatedly stably isolated what I believe to be the same cells for weeks at a time.
On the down side - the use of these tetrodes with Axona Ltd. wire-wrap style 4-tetrode drives can be challenging. For exactly the same reason that these tetrodes are so stiff, they can be a real pain to wire wrap. The industrial insulation must be scrapped or burnt off - but because the wire contained within is not as strong it is frequently damaged in the process. Even if successfully exposed, the nichrome wire is not particularly maleable. For these drives, it is worth going with a whole different wire: platinum iridium. I'm sorry to say that I do not have the specs available for this wire at this point, I'll have to write about that wire in particular later.
All the best,
e
1 comment:
we just had the same issue. thanks for the post. i think we are going to order the Kanthal wire you discussed. did you have to special order the adhesive coating or did they have it in stock? i guess i should just call them and ask...
Post a Comment